MICROLITE®
Toroidal Cores
|
|
CORE
DIMENSION
|
Performance
Parameters
|
|
Core
No.
|
O.D.Max
(mm)
|
I.D.Min
(mm)
|
Ht.
Max
(mm)
|
lm
(cm)
|
Ac
(cm2)
|
Vol
(cm3)
|
Wa
(cm2)
|
WaAc
(cm4)
|
Initial
Perm
|
AL*
(nH/N2)
|
| MP1005MDGC |
11.32
|
4.47
|
6.12
|
2.40
|
0.10
|
0.25
|
0.16
|
0.016
|
270
|
144.1
|
| MP1105MDGC |
12.19
|
6.07
|
6.29
|
2.80
|
0.10
|
0.27
|
0.29
|
0.028
|
270
|
116.5
|
| MP1205MDGC |
13.66
|
7.46
|
6.29
|
3.22
|
0.09
|
0.30
|
0.44
|
0.041
|
270
|
97.7
|
| MP1306MDGC |
14.67
|
7.46
|
7.87
|
3.37
|
0.15
|
0.51
|
0.44
|
0.066
|
245
|
137.8
|
| MP1603MDGC |
17.03
|
8.99
|
4.70
|
3.98
|
0.09
|
0.34
|
0.63
|
0.055
|
270
|
73.9
|
| MP1710MDGC |
18.68
|
12.16
|
11.05
|
4.74
|
0.20
|
0.94
|
1.16
|
0.230
|
245
|
128.5
|
| MP2010MDGC |
21.25
|
12.16
|
11.05
|
5.13
|
0.30
|
1.54
|
1.16
|
0.348
|
245
|
180.1
|
| MP2310MDGC |
24.35
|
12.16
|
11.05
|
5.60
|
0.43
|
2.38
|
1.16
|
0.494
|
245
|
233.7
|
| MP2510MDGC |
26.84
|
18.51
|
11.05
|
7.01
|
0.27
|
1.89
|
2.69
|
0.725
|
245
|
118.4
|
| MP2610MDGC |
26.92
|
15.97
|
11.05
|
6.61
|
0.37
|
2.48
|
2.00
|
0.751
|
245
|
174.6
|
| MP3210MDGC |
33.57
|
21.69
|
11.05
|
8.54
|
0.41
|
3.52
|
3.69
|
1.520
|
245
|
148.3
|
| MP3310MDGC |
34.06
|
14.70
|
11.05
|
7.49
|
0.71
|
5.34
|
1.70
|
1.210
|
245
|
292.9
|
| MP3505MDGC |
36.40
|
21.69
|
6.29
|
8.97
|
0.26
|
2.35
|
3.69
|
0.968
|
245
|
90.0
|
| MP3510MDGC |
36.52
|
18.51
|
11.05
|
8.48
|
0.66
|
5.58
|
2.69
|
1.770
|
245
|
238.9
|
| MP3710MDGC |
38.50
|
21.69
|
11.05
|
9.29
|
0.61
|
5.66
|
3.69
|
2.251
|
245
|
201.9
|
| MP4010MDGC |
41.58
|
21.69
|
11.05
|
9.76
|
0.73
|
7.15
|
3.69
|
2.706
|
245
|
231.1
|
| MP4510MDGC |
46.73
|
21.69
|
11.05
|
10.55
|
0.94
|
9.91
|
3.69
|
3.472
|
245
|
274.4
|
| MP7050MDGC |
13.23
|
7.46
|
6.12
|
3.14
|
0.08
|
0.25
|
0.44
|
0.035
|
245
|
78.2
|
| MP7089MDGC |
46.55
|
28.95
|
15.72
|
11.65
|
0.94
|
10.92
|
6.58
|
6.170
|
245
|
247.7
|
| MP7109MDGC |
57.21
|
37.44
|
15.32
|
14.64
|
1.03
|
15.13
|
11.01
|
11.376
|
245
|
217.4
|
| MP7120MDGC |
17.31
|
10.46
|
7.87
|
4.24
|
0.14
|
0.59
|
0.86
|
0.119
|
245
|
100.3
|
| MP7195MDGC |
54.32
|
26.97
|
16.52
|
12.49
|
1.60
|
19.98
|
5.71
|
9.136
|
245
|
394.1
|
| MP7206MDGC |
21.41
|
13.46
|
7.87
|
5.35
|
0.17
|
0.89
|
1.42
|
0.238
|
245
|
96.2
|
| MP7254MDGC |
39.38
|
24.86
|
15.65
|
9.91
|
0.75
|
7.46
|
4.85
|
3.656
|
245
|
234.1
|
| MP7310MDGC |
23.49
|
13.46
|
7.87
|
5.66
|
0.22
|
1.25
|
1.42
|
0.315
|
245
|
120.7
|
| MP7324MDGC |
36.99
|
23.01
|
11.05
|
9.24
|
0.49
|
4.50
|
4.16
|
2.026
|
245
|
162.3
|
| MP7350MDGC |
23.53
|
14.22
|
9.91
|
5.79
|
0.27
|
1.55
|
1.59
|
0.425
|
245
|
142.3
|
| MP7380MDGC |
18.30
|
10.23
|
7.87
|
4.35
|
0.17
|
0.74
|
0.82
|
0.140
|
245
|
120.6
|
| MP7438MDGC |
46.61
|
25.22
|
18.99
|
11.05
|
1.43
|
15.80
|
4.99
|
7.141
|
245
|
398.4
|
| MP7548MDGC |
33.25
|
19.73
|
11.05
|
8.15
|
0.47
|
3.82
|
3.06
|
1.435
|
245
|
177.4
|
| MP7585MDGC |
34.87
|
23.95
|
9.91
|
9.08
|
0.32
|
2.93
|
4.50
|
1.452
|
245
|
109.3
|
| MP7715MDGC |
51.53
|
32.46
|
13.89
|
12.97
|
0.89
|
11.57
|
8.27
|
7.379
|
245
|
211.7
|
| MP7930MDGC |
27.18
|
13.46
|
11.05
|
6.21
|
0.48
|
2.97
|
1.42
|
0.681
|
245
|
237.3
|
* µ and AL
are +/-15%. AL and
Bias are measurements based on
windings greater than 5 turns/cm
path length.
**
Boxes available for these sizes
soon . Other box materials available
on a limited basis for special
design. Contact Metglas, Inc.
for more Information.
Lm
= mean magnetic path length
AC = net cross sectional
area Wa = nominal
core window area
|
|
PACKAGING
Information
|
| LDGC
BOXED CORES |
|
| Flame
retardant, 25% glass fiber Nylon
resin |
|
| UL
File No. |
E41938
|
| Flammability
Rating |
UL94
V-0
|
| Electrical
Relative Temp.index |
130°C
|
|
DISCLAIMER
|
|
All statements, Information, and
data given herein are believed
to be accurate and reliable, but
are presented without guarantee,
expressed or implied. Statements
or suggestions concerning possible
use of our products,including
but not limited to the design
of switch mode power supply transformers
utilizing our products, are made
without representation or warranty
that any such use is free of patent
infringement,and are not recommendations
to infringe any patent. The user
should not assume that all safety
measures are indicated,or that
other measures may not be required. |
BACK
|